Issue 1, March 2008 Model 761/771 User Guide
Page 24 Studio Technologies, Inc.
for Surround
Default: Reference level set for fully attenuated (minimum) monitor output level.
Note: The 5-second delay is a safety feature ensuring that the reference level will not be accidently changed.
To permanently store the new value, you must still exit the confi guration mode.
Model 771 Confi guration—Reference Level
Press and hold the Reference Level button for 5 seconds to take a
“snapshot” of the level control’s setting at the time confi guration mode
was entered. The Reference Level LED will fl ash when the button is
initially pressed and then light solid when the “snapshot” has been taken.